14/4 Unshielded NYC Approved FPLP Fire Alarm Cable | 150C LL39

14/4 Unshielded NYC Approved FPLP Fire Alarm Cable | 150C LL39

$760 $145
Save 81%

14 AWG 4-Conductor Unshielded FPLP (Fire Power-Limited Plenum) Fire Alarm Cable is a high-performance, New York City (NYC) Certified, plenum-rated signaling circuit engineered for critical high-rise life-safety networks. Designed to…

  • img 100% Secure Payment & Data Safety
  • img Global Delivery & Fast Dispatch
  • img 30 Days Free Return & Exchange

14 AWG 4-Conductor Unshielded FPLP (Fire Power-Limited Plenum) Fire Alarm Cable is a high-performance, New York City (NYC) Certified, plenum-rated signaling circuit engineered for critical high-rise life-safety networks. Designed to operate reliably under challenging structural environments with a specialized continuous maximum thermal rating of 150 degrees C (LL39 specification), this cable features four robust solid bare copper conductors, premium high-temperature fluoropolymer insulation, and a low-smoke, flame-retardant fluoropolymer outer jacket.

This specialized 14 AWG multi-conductor profile is explicitly certified and approved for use within New York City’s demanding high-rise building codes (NEC Article 760 and Local Law 39 parameters). It balances heavy-duty current capacity with excellent mechanical layout flexibility. Because it is unshielded, it features a reduced outer diameter and faster stripping times, making it the ideal choice for multi-zone notification appliance circuits (NAC), speaker/strobe combinations, and power-critical signaling lines where electrostatic noise protection is not required. It can be installed directly in environmental air plenums, air-handling ducts, drop ceilings, and open architectural vertical shafts without requiring protective metallic conduit.

CABLE AMPACITY & SIGNALING DATA

Because fire alarm systems operate under specialized power-limited and life-safety signaling profiles, standard high-current electrical ampacity charts do not apply directly to standard branch operations.

  • Maximum Signaling Current Capacity: 6.0 AMPS (Per Conductor) This represents the maximum safe current limit for continuous multi-conductor notification appliance circuits (NAC) or auxiliary power loops under normal ambient facility conditions.

  • National Electrical Code Restrictions: FPLP fire alarm loops must be supplied by a power-limited fire alarm (PLFA) transformer or signaling panel circuit breaker. Overcurrent protection is capped natively by the fire alarm control panel (FACP), typically restricted to a class-limited 3.0 Amp to 4.0 Amp maximum output per notification loop to protect structural integrity during prolonged emergency alerts.

Key Features

  • NYC Local Law 39 (LL39) Certified: Formulated to meet the strict physical and thermal test standards required for high-rise commercial structures within New York City jurisdiction, ensuring structural stability and electrical integrity under extreme environmental heat.

  • 150 degrees C Continuous Thermal Performance: Features an advanced 150 degrees C high-temperature capability, providing an extra safety margin over standard 75 degrees C or 90 degrees C fire cables during structural heat spikes or machinery compartment proximity.

  • Mid-to-Heavy Gauge Voltage Drop Mitigation: The robust 14 AWG conductor profile significantly reduces line resistance compared to standard 16 AWG or 18 AWG wires, making it the ideal choice for long runs or highly populated notification appliance circuits.

  • Unshielded Configuration: Eliminates the overall foil shield and drain wire to reduce the cable’s outer diameter and weight, allowing for easier pulling through crowded raceways and quicker terminations at field junction boxes.

  • Plenum Rated (FPLP) Architectural Freedom: Outer low-smoke jacket is fully compliant with NFPA 262 and UL 910 flame propagation tests, allowing code-compliant installation in drop ceilings and open-air plenum return spaces without the need for structural steel conduit.

  • High-Purity Solid Bare Copper: Manufactured with premium solid copper conductors to deliver optimal electrical continuity, low line resistance, and minimal voltage drop over long linear field runs.

Common Applications

  • Multi-Zone Notification Appliance Circuits (NAC): Powering arrays of synchronized horns, high-intensity strobes, and facility emergency exit beacons.

  • Voice Evacuation & Emergency Audio Systems: Routing high-fidelity, low-attenuation voice audio lines and emergency speaker grids across multiple building zones where external electromagnetic interference is not a factor.

  • Dual-Circuit Emergency Control Feeds: Simultaneously routing primary power and signal returns for smart detectors, manual pull stations, and control modules back to the main command station.

  • HVAC Smoke Control Interlocks: Interfacing fire control logic directly with automated plenum smoke dampers, fresh-air intake shutters, and ventilation override switches.

  • High-Rise Life-Safety Infrastructure: Deploying critical safety paths in skyscrapers, commercial complexes, healthcare facilities, and crowded transit hubs subject to strict local municipality codes.

Cable Layer Architecture (From Core to Jacket)

  1. Conductors: 4 Independent 14 AWG solid bare copper lines.

  2. Conductor Insulation: High-temperature Fluoropolymer (FEP), color-coded using the specific NYC 2-pair pairing arrangement matrix (Black, Red, Yellow, Green).

  3. Core Wrap: Clean assembly binding to optimize flexibility and facilitate jacket stripping.

  4. Outer Jacket: Heavy-duty, low-smoke, flame-retardant Red Fluoropolymer skin featuring continuous surface-stamped NYC Certification and LL39 labeling text.

Circuit Identification: NYC Approved Color Layout

  • Conductor 1: Black Insulation (Pair 1 – Signal Negative)

  • Conductor 2: Red Insulation (Pair 1 – Signal Positive)

  • Conductor 3: Yellow Insulation (Pair 2 – Auxiliary/Audio Positive)

  • Conductor 4: Green Insulation (Pair 2 – Auxiliary/Audio Negative)

Technical Specifications

  • Conductor Size: 14 AWG

  • Number of Conductors: 4

  • Conductor Type: Solid Bare Copper

  • Insulation Material: High-Temperature Fluoropolymer (FEP)

  • Shielding Type: Unshielded

  • Jacket Material: Low-Smoke, Flame-Retardant Fluoropolymer – Red

  • Voltage Rating: 300 Volts RMS Maximum

  • Maximum Temperature Rating: 150 degrees C Continuous Operating (LL39)

  • Flame Test Ratings: NFPA 262, UL 910 Plenum Flame Test

  • Compliance Standards: NEC Article 760 (Type FPLP), NYC Local Law 39 (LL39 Approval), UL Listed, RoHS Compliant

Technical Note: Unshielded fire alarm cable is highly efficient for high-current notification circuits (horns and strobes) and speaker lines. However, for microprocessor-controlled addressable signaling line circuits (SLC data loops) or data communication tracks sharing pathways with high-voltage power lines, a shielded cable variant should be evaluated to mitigate potential electromagnetic cross-talk.

CABLE TYPE: 14 AWG / 4-Conductor Solid Unshielded Plenum-Rated Type FPLP 150 degrees C Life-Safety Cable (Black/Red/Yellow/Green Configuration)

DISCLAIMER: The technical information provided is for general reference only. Fire alarm systems and life-safety signaling circuits must strictly adhere to NFPA 72 (National Fire Alarm and Signaling Code), the National Electrical Code (NEC), local New York City Building Department amendments, and specific manufacturer guidelines. Always cross-reference the official product submittal data sheet from the chosen manufacturer prior to finalizing life-safety circuit layouts, system voltage drop calculations, or pulling structural cable lengths.

We offer fast and reliable shipping worldwide. All orders are carefully packaged and shipped within 1–3 business days after payment confirmation.

  • Fast shipping within 1-3 business days
  • Free shipping on orders over $40
  • 30 days money back guarantee
  • 24/7 online customer support
  • Secure packaging & safe delivery

Standard shipping, expedited shipping and express delivery options are available at checkout. Delivery time depends on your destination country and local logistics.

Only logged in customers who have purchased this product may leave a review.

You might also like

Add Related products to weekly line up

Special Ofers For Subscribers

Ten Percent Member Discount